TE Connectivity's Blood Pressure Monitoring with Sensors

Top Quote TE Connectivity's (TE) 1620 and 1630 series pressure sensors are a fully piezo-resistive silicon pressure sensor for use in invasive blood pressure monitoring. The sensor is designed to be used with automated assembly equipment and can be dropped directly into a customer's disposable blood pressure housing. A plastic cap is attached to the ceramic substrate to provide an easy method of attachment. End Quote
  • (1888PressRelease) August 01, 2018 - Hong Kong - TE Connectivity's (TE) 1620 and 1630 series pressure sensors are a fully piezo-resistive silicon pressure sensor for use in invasive blood pressure monitoring. The sensor is designed to be used with automated assembly equipment and can be dropped directly into a customer's disposable blood pressure housing. A plastic cap is attached to the ceramic substrate to provide an easy method of attachment to the customer's assembly and protection for the sensing element. A dielectric gel is placed over the sensor to provide electrical and fluid isolation.

    Heart rate, respiratory rate, oxygen saturation, body temperature, and blood pressure are all vital signs. Blood pressure is the pressure exerted by circulating blood on the walls of the blood vessel. Arteries and veins have different pressure levels. Normal resting blood pressure in an adult is approximately 120/80mm Hg. The two categories for blood pressure measurement are non-invasive blood pressure (NIBP) monitoring and invasive blood pressure (IBP) monitoring.

    Non-Invasive Blood Pressure Monitoring
    The principle of an auscultator is that the rubber cuff stops the blood flow so the stethoscope or pressure sensor does not detect any pressure. When the valve is released and the artery is opened, the blood flow causes pressure fluctuation in the cuff which is recorded by a stethoscope or pressure sensor.

    For each heartbeat, blood pressure varies between systolic and diastolic pressures. Systolic pressure is peak pressure in the arteries, which occurs near the end of the cardiac cycle when the ventricles are contracting. Diastolic pressure is minimum pressure in the arteries, which occurs near the beginning of the cardiac cycle when the ventricles are filled with blood.

    Patients with instable hemodynamics are not advised to use NIBP monitoring as it does not provide accurate measurements for the following reasons:

    NIBP does not provide continuous pressure monitoring

    NIBP does not provide the wave of pressure

    Invasive Blood Pressure Monitoring

    Arterial blood pressure is most accurately measured invasively through an arterial line. Invasive arterial pressure measurement with intravascular cannula involves direct measurement of arterial pressure by placing a cannula needle in an artery (usually radial, femoral, dorsalis pedis or brachial).

    The cannula must be connected to a sterile, fluid-filled system, which is connected to an electronic pressure transducer. This invasive technique is regularly employed in human and veterinary intensive care medicine, anesthesiology and for research purposes.

    IBP provides various clinical values. In surgical applications, the blood pressure is continuously and accurately measured, allowing medical staff to react to changes faster. For example, if anesthesia is given to the patient, the continuous monitoring can confirm it has not caused an adverse effect to the blood pressure. During certain operations, maintaining blood pressure in a very narrow range is critical; IBP creates the capability to monitor and maintain pressures. IBP also plays a critical role in situations where blood pressure is expected to fluctuate rapidly. By continuously monitoring the pressure, medical staff can be more timely and accurate in their reactions.

    When to use:

    NIBP is not possible to use or when greater accuracy is required

    Blood pressure must be maintained in a very narrow range for a period of time

    Blood pressure is expected to fluctuate significantly

    Continuous blood analysis is required

    As an authorized distributor for TE, Heilind Asia provides TE products and also value added services. Heilind Asia supports both original equipment and contract manufacturers in all market segments of the electronics industry, stocking products from the industry's leading manufacturers in 25 component categories, with a particular focus on interconnect and electromechanical products.

    About Heilind Electronics:

    Founded in 1974, Heilind Electronics, Inc. (www.heilind.com) is one of the world's leading distributors of connectors, relays, switches, thermal management & circuit protection products, terminal blocks, wire & cable, wiring accessories and insulation & identification products. Heilind has over 40 facilities in the United States, Canada, Mexico, Brazil, Germany, Hong Kong, Singapore and Mainland China.

    Heilind Asia Pacific (www.heilindasia.com) commenced operations in Dec 2012, and now has 20 locations throughout Asia. Its industry leading service offering to customers in Asia Pacific is the result of a commitment to the belief of "Distribution As It Should Be". Learn more at www.heilindasia.com and on Facebook, WeChat, Weibo and Twitter.

    About TE CONNECTIVITY:
    TE Connectivity Ltd. (NYSE: TEL) is a $13 billion global technology and manufacturing leader creating a safer, sustainable, productive, and connected future. For more than 75 years, our connectivity and sensor solutions, proven in the harshest environments, have enabled advancements in transportation, industrial applications, medical technology, energy, data communications, and the home. With 78,000 employees, including more than 7,000 engineers, working alongside customers in nearly 150 countries, TE ensures that EVERY CONNECTION COUNTS. Learn more at www.te.com and on LinkedIn, Facebook, WeChat and Twitter.

    TE Connectivity, TE, TE connectivity (logo), and EVERY CONNECTION COUNTS are trademarks of the TE Connectivity Ltd. family of companies.

    Other logos, product(s) and/or company names might be trademarks of their respective owners.

    Press Contact:
    sarah luo
    Heilind Asia Pacific
    RM 1707-10,DELTA HOUSE,3 ON YIU ST
    26119634
    http://www.heilindasia.com/

    ###
space
space
  • FB Icon Twitter Icon In-Icon
Contact Information